Friday, March 11, 2022

Most Common vessel's detainable deficiencies to avoid accordingly

 



pls take into consideration the following most common deficiencies which cause detention to avoid accordingly in co-operation with the company :

1.Fire Safety

  • Inoperable fire detection and alarm system
  • Wasted/Inoperable fire-dampers 
  •  Malfunction of fire pump 
  • Poor closing condition of fire door 
  • Insufficient pressure from emergency fire pump

2.Water/Weathertight Conditions

  • Damaged/seized ventilators 
  •  Hatch covers wasted cleats and its spacers 
  •  Hatch cover rubber gasket missing/wasted


3.Life Saving Appliances

  • Lifeboat engine not started easily
  •  Rescue boat engine not started easily 
  • Inoperative davit for launching arrangements for survival craft 
  •  Emergency generator do not start automatically or manually Structural Conditions  Correctly mounted Hydrostatic Release Unit (HRU) on an inflatable liferaft
4.safety navigation

  • Charts not updated 
  •  Navigation charts for intended voyage not available 
  • Nautical publication not updated 
  • Nautical Publication for intended voyage not available
  • Voyage data recorder (VDR / S-VDR) malfunction ‘’system error’’
  •  Navigation lights damaged/inoperable 
  • Echo Sounder malfunction 
  •  Main gyro compass not aligned with repeaters 
  •  Passage or Voyage plan not as per guidelines Res A.893

5.MARPOL Annex IV
  • Inoperative sewage treatment plant

6.MARPOL Annex I

  • Oil filtering equipment, 15 ppm alarm arrangements and discharge connection should be in good condition, properly calibrated, maintained and fully functional, with appropriate spares.
  • Oil record book not updated 
  • Excessive quantity in Oily bilge and Sludge tanks
7.Structural Conditions

  • Emergency shut off valves of oil tanks inoperative 
  • Ballast tanks heavily corroded/wasted
  • Cracks in hull, keel plate connections and pin
  • Bulkheads heavily corroded/waste/holed
8.Propulsion and Auxiliary Machinery

  • Cleanliness of Engine Room insufficient
  • Gauges, thermometers inoperable/damaged
9.ISM

  • Records of inspection, maintenance, testing and drills and crew familiarization with fire and abandon ship drills
  • Lifeboat weekly test NOT conducted and recorded
  • Rescue boat weekly test NOT conducted and recorded
 